Skip to content
AlbionFalls Lock Experts
Open 24/7(289) 203-0748Open 24/7
Detached horizontal exit device and separate strike component on a workshop bench. — Panic & Exit Hardware, Hamilton
Person holding a door-handle and latch assembly at a worktable outside a glass entrance, with additional handles and tools laid out. — Commercial Rekeying, Hamilton

Commercial · Hamilton

Panic & Exit Hardware

The fire inspector's note is blunt: the banquet hall's second exit still turns on a deadbolt, and the crowd it is rated to hold needs a door that opens under one motion, no key involved.

Call (289) 203-0748

In plain words

A tenant fit-out is a common point to bring exit hardware into a space for the first time. As walls move and a room's intended use becomes clear, the doors serving it get measured against that use: occupancy, fire rating, width and whether the space now qualifies as an assembly occupancy. Specifying and fitting the hardware alongside the rest of the fit-out, rather than after an inspector flags it, keeps the schedule intact and gives the space a documented exit from the day it opens.

Sound familiar?

The daycare wants the yard gate and the classroom door alarmed so a staff member hears the moment it opens, without turning either into something a child could be shut behind.

How the visit goes

Panic & Exit Hardware

How the visit goes

Wooden door with a dark lever handle and empty round bore, beside a deadbolt, latch, screws and screwdriver on a case.
Kneeling technician using a small tool at the handle set of a black door, with an open tool bag and yellow flowers.
  1. Reading the door itself

    Every opening gets the same close look: whether it is fire-rated, which way it swings, how wide it is, and what preparation, if any, already exists in the door and frame from earlier hardware. A hollow-metal fire door takes a different device than a wood door in a non-rated partition, and a narrow-stile aluminum storefront door narrows the choice of device further still. Reading this correctly before anything is ordered is what keeps the installation from turning into a second visit once the wrong device arrives and does not fit the preparation already in the door.

  2. Recording what was fitted

    The visit closes with a written account of the work: which device went on which door, its type and rating, the outside trim fitted, any electrified function added, and the tests the assembly passed. This record travels with the building rather than staying in the locksmith's memory, so a fire inspector, an insurer or a new manager reviewing the space later has a clear account of the exit hardware and when it was fitted.

  3. A door that opens under one motion, every time

    What the space has afterward is straightforward: anyone inside can leave through that door with a single push on the crossbar or touchpad, no key, no second step, no need to remember which way a lock turns. Staff can be shown the motion once and it stays intuitive, because that is exactly what the hardware is built to do. Outside, entry still works the way it was set up to, through the trim chosen for that door, entirely separate from the exit function inside.

Panic & Exit Hardware

In the van

  • Rated exit device

  • Through-fixings and mounting hardware

  • Dogging key or keyed cylinder

  • Signage and labels

  • Astragal and mullion hardware

Handheld diagnostic unit with a screen and buttons lying on a dirty car floor mat, cabled to a port under the dash.

Panic & Exit Hardware

What affects the quote

  1. Number of openings involved

    One door with a single device is the simplest case. A building with several affected exits, such as doors from a stairway plus an assembly-room exit, is quoted as the sum of each opening's own work.

  2. Condition of the existing hardware

    A device that only needs adjustment, cleaning and new fasteners costs less in labour than removing a seized or badly worn device and fitting a replacement in its place.

  3. Weatherproofing for an exterior opening

    An exterior device, strike and trim built to handle temperature swings and moisture cost more as hardware than an equivalent interior-only set, and the quote reflects that difference in the parts themselves.

What to have ready

  • Is any door part of a pair with a second leaf?
  • Has a fire inspector or building official already flagged a specific door?
  • Is this for new construction, a renovation, or an existing building?
Call (289) 203-0748

Panic & Exit Hardware: questions

Questions
How often does this hardware need to be checked?

Fire door assemblies, including their exit hardware, are inspected and tested on a set schedule, and it is practical to check any exit device on the same rhythm even where the door is not fire-rated. A brief check for a stiff crossbar, a latch that no longer seats fully, or a strike that has drifted is enough to catch most wear before it becomes a callout.

How high should the crossbar or touchpad be mounted?

Exit-device makers publish a mounting range for their own models, and in practice a crossbar or touchpad sits no higher than about 1200 mm above the finished floor. The locksmith sets the hardware inside the maker's range and below that ceiling, allowing for anyone in the space who needs a lower reach, a wheelchair user or a shorter staff member among them.

Can I still lock the door from outside?

Yes. The releasing device only governs the inside of the door; the outside gets its own trim, a pull, a lever with a cylinder, or a keyed cylinder alone, chosen for how that door is entered. Locking or unlocking that outside trim has no effect on the inside crossbar, which always releases the latch under a push, so entry security and exit function are handled as two separate questions.

Related services

Panic & Exit Hardware near you

Call(289) 203-0748

Request a visit

Or call (289) 203-0748 · open 24/7